Battery Storage
The battery should be stored under the following conditions.
(1) Low humidity
(2) 5 to 122℉(-15 to 50℃)
(3) Clean, and avoid direct sunlight.
After long term storage, all batteries deliver less than rated capacity on first cycle. In cyclic
application, full capacity may be obtained through several charge/discharge cycles,
typically 2-3 cycles.
When batteries are placed in extended storage, it is recommended that they receive a refresh
charge at recommended intervals as following;
Refresh charging method:
3 to 5 hours of constant current 0.1C Amps or 12 to 16 hours at constant voltage of 2.45V/cell
Storage Ambient: Recommended Interval
Storage Ambient: |
Recommended Interval |
Below 20℃ (68℉): |
12 months |
20 to 30℃(68 to 86℉): |
6 moths |
30 to 40℃(86 to 104℉): |
3 moths |